GIGE camera "removed" when using IMAQdx or NIMAX

$
0
0

I have an Allied Vision GIGE camera: when using the manufacturer's SW or 3rd party apps we can stream images continuously without problem.  When access the camera from NIMAX or labview code with IMAQdx functions, I lose communication with the camera and after a period of time getting images from the camera.  After a short period of time the LV App stops and we get the error:

 

Error -1074360308 occurred at IMAQdx Get Image2.vi "Camera is Removed"  (or similar depending on which IMAQdx vi i'm using to access the camera)

When this happens the camera is no longer visible on the network (to any app) and the camera needs to be rebooted to reconnect.  The odd part is this only happens when accessing the camera from labview or NIMAX.  Camera runs fine with non NI apps, but something about the interaction with labview causes the camera to stop communicating when images are being transferred.  It is noted that the slower the frame or data rate the longer this takes to happen,  but it eventually it does happen in any configuration I've tested.

Same behavior is observed with both Labview 2019 sp1 and 2023, and with multiple routers/switches. firewall on/off, etc.

 

I'm using the NI high performance GIGE driver, have repaired and reinstalled LV, and yes Jumbo packets is on.

Similar behavior has been reported on a couple of other threads, but not recently and without resolution.  

 

Thoughts?

A vi that produces this behavior is attached.  