Quantcast
Channel: Machine Vision topics
Browsing all 1272 articles
Browse latest View live

How to calculate time difference using calculator in VBAI

Is anyone know how to use calculator step to calculate the time difference? Or is there any other way to calculate time difference without using calculator? Thank you

View Article


Image may be NSFW.
Clik here to view.

LabVIEW VDM to display OCR threshold image

Hi Everyone, I am developing OCR reading application using LabVIEW 2020 + VDM 2020 SP1.I have a problem that I cannot display image from OCR thresholding (linear and non-linear method).It would be...

View Article


Unable to load XML file in NI-MAX for Allied Vision Manta_G 145B. IMAQdx v. 20.6

I try to migrate from LV2014 to LV2020. If I try to open Allied Vision Manta_G 145B camera in NI-MAX i get Error 0xBFF6901D "unable to load xml file". IMAQdx Version is 20.6 (RT + Dev). Basler Cameras...

View Article

Password Protection to avoid closing inspection interface in VBAI

Dear Team, I was wondering if there is a way to prevent closing the program running in inspection interface view.If someone wants to close the software then it prompt to enter password and until...

View Article

Is 1.5MP camera suitable for OCR

We want to use Ni labview for OCR in a pharmaceutical application.We are printing 5 lines using font OCRB 2 mm.We have high rejection value and mis recognition between 0 and o, between R and P and...

View Article


VBAI 2020 Run Labview VI Problem

 Hello,I am trying to implement a functionality to VBAI 2020 by using Run Labview VI step.This LLB, I am using since VBAI 2015 worked fine in VBAI 2018 and VBAI 2019. It just requires me to save the...

View Article

Image may be NSFW.
Clik here to view.

Inspection THT components PCBA with light distortion

Hi,I'm valuating the opportunity to perform a vision test on the THT components in our production line. I'm wondering if NI Vision is robust to tolerate the external light distortion ( we have closed...

View Article

Access Violation Crash with imgSequenceSetup

Hello,I am working on an OCT system with a PCI-6259 for scanner control and a PCIe-1433 for camera control. I am currently implementing the system in an open source OCT software (OCTProZ).OCTProZ...

View Article


Vision Builder get stuck with restricted network

Hi. I have some industrial inspection stations running Vision Builder AI 2015 F3. When I restart the CPU for some reason the VB program doesn't start and I have to wait 10 minutes more or less, a...

View Article


Multiple Optris PI-640 Cameras

Hello, I have two Optris PI-640 cameras and I have the Optris LabVIEW driver (DLL). This comprises two sets of functions, single and multiple, e.g.evo_irimager_usb_init...

View Article

How to change NI-IMAQdx camera ping rate

Hi all, Does anyone know if it is possible to change the rate IMAQdx sends "discovery ping" to network adapters to discover GigE cameras?I don't need to turn this completely off, just reduce the flood...

View Article

What "real" data type is the "command" type returned by IMAQdx "Enumerate...

The IMAQdx "Enumerate Attributes" function can return an "Attribute Type" which include U32, I64, DBL, String, Enum, Bool, and Command.  What does Command translate into in terms of "real" LabVIEW data...

View Article

Image may be NSFW.
Clik here to view.

Image Prespective Error

Hi, The image of part to be inspected using camera and product in perpendicular direction. 1. Basler Camera :Basler acA2440-20gm Sensor Format2/3'' Sensor TypeCMOS Sensor Size8.4 mm x 7.1 mm Resolution...

View Article


Distortion Model Calibration Error

Hello,I am trying to calibrate an Opto-E telecentric lens on VBAI.On the mechanical setup, everything is fine. Telecentric lens, suitable industrial camera, telecentric illumination etc.Using a...

View Article

imgSessionConfigure takes several seconds

Hello, I am now building an OCT system using 2048R InGaAs High Speed Linescan Camera. I use NI-PCIe-1433 to control it grabbing image. The camera configuration, imgSessionConfigure, takes about 5-7...

View Article


Image may be NSFW.
Clik here to view.

Why can't I run the opencv dll?

My parameter are imagein1, imagein2, outputstr.And the debug and release for making dll was successful.   But when I try to test it simply, an error occurs, I can't run. <The library specified for...

View Article

Error -1074360271 occurred at IMAQdx Start Acquisition

Dear all,I am using a Hitachi HV-F202 camera (GigEVision CCD) and I try to run it in labview. I conntected my camera via a docking station and ethernet cable. However, I cannot start my labview code...

View Article


Image may be NSFW.
Clik here to view.

Error 0xBFF69001 ,Error 0xBFFF8009 with PXIe1435 and Basleer acA2040-180kc...

    I have some trouble using NI PXIe-1435 (NI 1435) and camera.The camera is Basler acA2040-180kc.    After I selected the ACA2040-180KC (Base) camera configuration, there was no way to change the...

View Article

Variable height image acquisition using line scan camera Basler 6144-16gm,...

Hello, I'm developing prototype of an inspection system which will acquire variable height images using a line-scan camera. Frame-start and frame-stop actions to be controlled by software triggers....

View Article

Vision Assistant will not create labview code

Hi trying to create Labview code from vision assistant. When I click on create labview code it tries to find nirio_FindDevice which it cannot and I searched for it and I don't have it on my machine....