IMAQdx Get Image 2.vi error and IMAQdx Open Camera.vi error

Hey I was using a LabView based program that connects a camera and function generator waveform. When the waveform of the pulse delivered to the dispenser it triggers the camera to turn on. However, an...

View Article


IMAQdx Get Image2. vi error

Hey I was using a LabView based program that connects a camera and function generator waveform. When the waveform of the pulse delivered to the dispenser it triggers the camera to turn on. However, an...

View Article


inside advanced edge detection

Hi all,I need to understand how edge detection works to measure parts in direct light (with reflections on the surface).It is clear to me the use of various filters such as sobel or canny but the edges...

View Article

Image may be NSFW.
Clik here to view.

LabVIEW hangs on IMAQ call

LabVIEW hangs periodically and when I look at where it hangs, lately it's been in an IMAQ call.  It is occurring quite frequently and I've tried repairing LabVIEW and IMAQ, and also...

View Article

Image may be NSFW.
Clik here to view.

AVI file size is still limited to 2 GB for all system codecs

Since the AVI functionality overhaul in VDM 2012 SP1 (archived) maximum AVI file size has been limited to 2 GB. In VDM 2019 this issue was reported to be fixed (archived) under CAR #428570.There is...

View Article


Image may be NSFW.
Clik here to view.

Memory leak in NI Route Coordinator service with multiple USB 2.0 cameras

Environment:Windows 8.1LabVIEW 2018 SP1 f4 - 2020Vision Development Module 2018 SP1 - 2020Vision Acquisition Software 18.5.1 - 20.0 Steps to Reproduce:Connect 4+ USB 2.0 cameras to a PC or create a...

View Article

Image may be NSFW.
Clik here to view.

Multiple bugs in AVI Codec Comparison example

Environment:Windows 8.1LabVIEW 2018 SP1 f4 - 2020Vision Development Module 2018 SP1 - 2020 Steps to Reproduce:Launch LabVIEW, open Help menu and select Find Examples...;In Example Finder navigate to...

View Article

Tap Configuration for PCIe-1427 Framegrabber

Hi,I am still new to Vision and camera file generation, so I hope I am understanding things right.I am using a CIS sensor (like a line scan camera) from Tichawa Vision, which is connected via...

View Article


Image may be NSFW.
Clik here to view.

Terrible performance of VPx codecs, especially at high resolutions

I've made an HD version of AVI Codec Comparison example based on stock Vision images, I think you'll find it useful as well. It takes about 3 min. and 500 MB to execute.I also added a score which tries...

View Article


Build CoordSys

Hi, I am missing something in this function. In my application, I detect a series of points in the image referred to the image origin (0;0). I want to refer the coordinates of all the points detected...

View Article

Image may be NSFW.
Clik here to view.

Angle value in results of IMAQ Find Straight Edges 3 VI

Hello everyone, I'm working on a project for automated machine vision system using NI Vision.One of the tasks is detect straight edge of the object. So, I'm using IMAQ Find Straight Edges 3 VI and I...

View Article

KnowledgeBase article for RT targets is outdated?

https://knowledge.ni.com/KnowledgeArticleDetails?id=kA00Z0000019KYuSAM says that "Since there are currently no sbRIO targets with two ethernet adapters, IP cameras are not currently supported on...

View Article

Pattern matching can lose some matches when used with some advanced options

IMAQ Match Pattern 4 VI can lose some matches with an appropriate score when used with some advanced options (Max Pyramid Level, Match List Reduction Factor).This bug is somewhat similar to CAR #718023...

View Article


Vision Assistant shows incorrect pattern matching results for some images

Environment:Windows 8.1LabVIEW 2018 SP1 f4 - 2020Vision Development Module 2018 SP1 - 2020 Steps to Reproduce:Download all attached files;Open the script and the test image in Vision Assistant;Switch...

View Article

Loosing data Packet while using same caemra two times in VBAI program

Dear Team, I am using same camera in two different states in my VBAI program. By doing so I am loosing data packets and it leads to create lines on the images. I tried following steps:1.  set "test...

View Article


Hardware synchronized image acquisition

Hi friends, Here is my system's hardware config:2x NI 1433 frame grabber1x NI 6323 Multifunctional DAQInterconnected using an RTSI. Software setup:3 counters Ctr0, Ctr1, Ctr2 to trigger each line...

View Article

Single camera to use two times with different exposure

Dear Team, I am using single camera two times with different exposure value in my VBAI program. Sometime I am getting an image that has been acquired prior to the exposure time change.So. could you...

View Article


Does Labview Vision can achieve motion measurement with approximatety 1-10...

DearI‘m just beginning to learn machine vision. My English is not very well,, sorry for my poor English.Now, I have a requirement that achieve motion measurement with 1-10 micron accuracy. The...

View Article

imaqSelectRect missing for NI Vision 2020 in LabWindows

Hello, I would like to allow a user to select a rotated rectangle from an image acquired from a camera.  The function imaqSelectRect looks to be exactly what I need (and is included in the help file)....

View Article

Image may be NSFW.
Clik here to view.

I want to run the astro pro camera module in LabVIEW

Astra PRO camera products from Orbbec company△This is the Orbbec company's Astra PRO camera product. I tried to connect this camera to myRIO and output the video in LabVIEW. So, I tried to connect...

View Article